Outdoor microphones
Showing all 4 results
-
Norsonic NOR1216 Outdoor Microphones
Read moreDiscover the Norsonic NOR1216 Outdoor Microphones — engineered for precise, standards-compliant acoustic measurements. Features Fulfils IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1 (frequency correction applied). Protection class IP 55 (dust and water). Easy to calibrate with a normal ½” sound calibrator. Microphone verification by SysCheck facility. Low self noise – typically below 17 dB, A-weighted. Delivered with individually calibration certification. Built in heating for enhanced weather protection. Directly powered and supported by Nor140, Nor145 and Nor150 (built in selectable frequency correction networks, heater supply and SysCheck signal generator). Type approved by PTB, Germany. Standards IEC 60651 IEC 61672 ANSI S1.4 Specifications Acoustic performance: IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1 (frequency correction applied) with a suitable instrument (Nor140/Nor150). Max sound pressure level: >140 dB peak dependent on supply voltage. Microphone cartridge: Nor1227 or Nor1225 (1/2” 50 mV/Pa) Polarization voltage: 0 volt (Nor1227) 200V (Nor1225) Inherent noise: < 17 dB A-weighted Reference direction: Vertical or horizontal dependent on the applied frequency correction Ingress Protection Category: IP55 according to IEC 60529. Supply voltage: ±14 volt to ±16 volt Current consumption: 18mA incl. heating. Connector: 7 pin Lemo type 1B male Temperature range: -40ºC to +85ºC Height: 375 mm / 14.8”(1” pipe mounting), 450 mm / 17,7” with tripod adaptor Diameter: Approx 80 mm / 3.1” (with windshield) Weight: Approx 300 g (with preamp microphone) Mounting thread: Standard 1” pipe threads according to ISO 228. When using the tripod adapter: 3/8” UNC.
-
Norsonic NOR1217 Outdoor Microphones
Read moreExplore the Norsonic NOR1217 Outdoor Microphones — engineered for precise, standards-compliant acoustic measurements. Features Outdoor microphone for community and aircraft noise. Fulfils IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1 (when used with Nor140, Nor145 and Nor150 sound level meters). Protection class IP 55 (dust and water). Easy to calibrate with a normal ½” sound calibrator. Microphone verification by SysCheck facility. Low self-noise – typically below 17 dB, A-weighted. Directly powered and supported by Nor140 and Nor150 (built in selectable frequency correction networks and SysCheck signal generator). Low cost. Use microphone and preamplifier supplied with Nor140, Nor145 and Nor150. Approved by PTB, Germany. Specifications Acoustic performance: IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1 (frequency correction applied) with a suitable instrumentMax Sound pressure level: >140 dB peak dependent on supply voltage. Microphone cartridge: Nor1227 or Nor1225 (1/2” 50 mV/Pa) Polarization voltage: 0 volt (Nor1227) 200V (Nor1225) Inherent noise: < 17 dB A-weighted Reference direction: Vertical or horizontaldependent on the applied frequency correction Ingress Protection Category: IP55 according to IEC 60529. Supply voltage: ±14 volt to ±60 volt Current consumption: 1,5mA Connector: 7 pin Lemo type 1B male Temperature range: -40ºC to +85ºC Height: 395 mm / 15.5”(without tripod adapter) Diameter: Approx 80 mm / 3.1” (with windshield) Weight: Approx 300 g (with preamp microphone) Mounting thread: 3/8” UNC
-
Norsonic NOR1218 Outdoor Microphones
Read moreExperience the Norsonic NOR1218 Outdoor Microphones — engineered for precise, standards-compliant acoustic measurements. Features IEPE Outdoor microphone for semi-permanent installations Outdoor microphone for community and aircraft noise. Directly powered and supported by Nor131 or Nor139 (built in selectable frequency correction networks). Fulfils IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1. Protection class IP 55 (dust and water). Easy to calibrate with a normal ½” sound calibrator. Low self noise – typically below 18 dB, A-weighted. Low cost – uses microphone and preamplifier supplied with Nor131 or Nor139 . Supplied with a accredited calibration certificate. Standards IEC 60651 IEC 61672:2013 ANSI S1.4 type 1. Specifications Acoustic performance: IEC 60651, IEC 61672 class 1 and ANSI S1.4 type 1 (frequency correction applied) with a suitable instrument (Nor131/Nor139). Max sound pressure level: >140 dB peak dependent on supply voltage. Microphone cartridge: Nor1227 or Nor1228 (1/2” 50 mV/Pa) Polarization voltage: 0 volt Inherent noise: < 18 dB A-weighted Reference direction: Vertical or horizontal dependent on the applied frequency correction Ingress Protection Category: IP55 according to IEC 60529. Supply voltage: IEPE Power consumption: 30 mW (dependent on supplied current) Connector: TNC Temperature range: -40ºC to +85ºC Height: 375 mm / 14.8”(1” pipe mounting), 450 mm / 17,7” with tripod adaptor Diameter: Approx 80 mm / 3.1” (with windshield) Weight: Approx 300 g (with preamp microphone) Mounting thread: Standard 1” pipe threads according to ISO 228. When using the tripod adapter: 3/8” UNC.
-
Norsonic NOR1297 Outdoor Microphones
Read moreExperience the Norsonic NOR1297 Outdoor Microphones — engineered for precise, standards-compliant acoustic measurements. Applications Construction site monitoring Harbour monitoring Airport monitoring Road/railway monitoring Plant monitoring About Norsonic was the first company to introduce sound recording of noise events in a sound level meter. This greatly improved the work to identify a noise event and to judge whether it should be excluded or not from the overall noise level. However, it’s quite time consuming to listen through numerous sound recordings. The three-dimensional Nor1297 Noise compass significantly reduces time spent on judging if a noise source should be a part of the overall noise calculation or not, simply by defining which direction the noise is coming from. When used together with Norsonic’s sound level meters and NorCloud, the device provides a three-dimensional vector pointing at the sound source. The system may also operate off-line and collect the data on the instruments SD card for later analyse in NorReview. Why should I get the Noise compass? Measure sound pressure as usual Use Norsonic sound level meter or noise monitoring station to monitor the sound pressure level of a site. Add dominant source detection Add the Noise Compass to your setup and measure the direction of the dominant noise source, in all three dimensions. Avoid listening – save time! The Noise Compass allows you to mark and filter out sources outside a region of interest. The nearby railway or passing airplanes can be detected automatically, no need to listen to verify. Calculate sound levels for the site Sound incident from directions not inside your definition of a site can be automatically marked and excluded from the measurement. The result is Leq or Lden values based on your site definition only. Features The noise is preprocessed with A-filters. The Noise Compass delivers data ten times a second. Directional data is exponentially smoothed in time to provide high precision indication The Noise Compass also handles impulsive sounds down to 10 ms duration. The Noise Compass provides a quality indicator to avoid false detection. An array of 8 MEMS microphones ensures full 3D sound incident detection. The unit receives power and sends data to Nor145 and Nor150 via a single ethernet cable. The unit is fully weather protected for harsh outdoor monitoring. Fits all existing outdoor microphones. The Noise Compass simply adds inn below the mic assembly. Noise Compass and NorCloud NorCloud is a Norsonic system to collect, display and process sound level data. When used together with a Norsonic Sound Level Meter, you can, measure, analyse and report directly from your web browser. Create projects, assign sound level meters to projects and configure settings such as audio recording, SMS/e-mail alarms and automatic reporting. NorCloud stores your data safely and conveniently, but you are of course free to download your measurements. Browse measurements Show your measurements as a function of time, and see the instantaneous direction. Analyse Check the noise distribution over a timespan in surface and scatter plots. Define sectors Create your own sectors to automatically generate markers on your measurements. Report Let NorCloud automatically generate reports in the interval you specify. Define sectors with horizontal and vertical plane boundaries and quality threshold. Any number of sectors are allowed, the resolution is 1 degree. Hover over the time series plot to see time instant direction. When the sound incidence matches your sector, the sector is highlighted. Look at the LAeq noise in both scatter and surface plot. The plots are generated for the timespan selected in the time series plot. Noise Compass and NorReview NorReview is a Norsonic desktop application for advanced analysis. Import measurements to do analysis according to several international and national standards. You can use the software to edit and annotate your measurements, calculate new functions. NorReview supports advanced report generation and customization of reports using Microsoft Excel. NorReview is widely acknowledged for its high flexibility and advanced functionality. Review Show your measurements as a function of time, and see the instantaneous direction. Mark Automatic marker generation for sectors defined in NorCloud. Calculate Generate new values for your measurements with markers included or excluded. Report Generate reports for your recalculated measurements. Use automatic marker calculation from NorCloud sector defines. Calculate global values for the markers regions or the measurement without the marker regions. NorReview results. Aircraft noise excluded in this measurement Use automatic marker calculation from NorCloud sector defines. Specifications Horizontal angle range: 0 to 360 degrees Vertical angle range: – 90 to 90 degrees Sound pressure level range: 40 to 123 dB SPL re. 20 µPa Operating conditions: Free-field Horizontal accuracy: ± 7.5 deg. , std. dev. typ. 2.0 deg. Vertical accuracy: ± 10 deg. , std. dev. typ. 4.0 deg. Calibration: Factory calibrated with certificate Operation principle: Multi-correlation Time resolution: 100 ms Filtering: A-weighting Time averaging: Exponential time and 10 ms max Instrument compatibility: Nor145 and Nor150 Software compatibility: NorCloud and NorReview Mounting: Nor1216 and Nor1217 compatible Ingress protection: IP55 Connectivity: Ethernet 100 mbps Power supply: 5V to 15 V passive power-over-ethernet Nor1297 calibration results – Typical performance and measurement uncertainty
